A wire mesh specification looks like a string of numbers, but each one changes how the filter performs. Read it correctly and you order the right part the first time; misread it and you get the wrong opening, the wrong strength, or the wrong flow. A complete spec should name at least five things — alloy grade, mesh count, wire diameter, weave type and the resulting aperture — plus the finish and any certification you need. Here is what each part means and how the numbers relate.
Mesh count
Mesh count is the number of wires (or openings) per linear inch, counted from the centre of one wire to a point one inch away. A higher mesh count means more, finer wires and smaller openings — 20 mesh is coarse, 100 mesh is medium, 325 mesh is fine. On its own, though, mesh count does not tell you the opening size, because it depends on the wire diameter too. This is the single most common ordering mistake: treating “mesh” as if it were a micron rating. It is not.
Wire diameter
The thickness of the individual wire, quoted in millimetres or inches (for example 0.10 mm or 0.0040 in). For the same mesh count, a thicker wire means a smaller opening and a stronger, but less open, cloth. Wire diameter is why two “100 mesh” cloths can have very different apertures and very different strength. A reputable supplier always states the wire diameter alongside the mesh count — if it is missing, the spec is incomplete.
Aperture (opening size)
The actual gap between adjacent wires — the number that really governs what passes through. For a square plain-weave cloth:
> Aperture = (25.4 mm ÷ mesh count) − wire diameter
So a 100 mesh cloth with 0.10 mm wire has an aperture of (25.4 ÷ 100) − 0.10 = 0.154 mm ≈ 154 µm. Change the wire to 0.14 mm and the same 100 mesh drops to roughly 114 µm. Always confirm the aperture, not just the mesh count — it is the value that corresponds most closely to filtration performance. Note that a woven-cloth aperture is a *nominal* rating: it is the physical hole size, not an absolute particle cut-off. If you need an absolute rating, sintered or Dutch-weave media is the better route — see woven vs. sintered wire mesh.
Open area
The percentage of the mesh surface that is open space, set by mesh count and wire diameter together. Higher open area means higher flow and lower pressure drop for a given face area, but a more open, less rigid cloth. Coarse plain weaves can exceed 50–60% open area; fine cloths fall well below that. When flow or pressure drop matters, open area is as important as the aperture itself.
Weave type
| Weave | Pattern | Typical use |
|---|---|---|
| Plain | Over-one, under-one; square openings | General filtration, coarse to medium |
| Twill | Over-two, under-two | Finer, stronger cloth than plain at the same wire |
| Plain Dutch | Different warp/weft counts, tapered pores | Fine filtration, high strength |
| Twill Dutch | Dutch + twill weave | Finest woven ratings, high dirt capacity |
The weave affects fineness, strength, dirt-holding and how the cloth behaves under pressure and backwash.
Grade and finish
The spec should also name the alloy: 304 for general service, or 316L where chlorides, salt or aggressive chemistry are present. If you are unsure which to specify, read 304 vs. 316L stainless steel filter mesh. For process-critical parts, also call out passivation to ASTM A967 and, if required, an EN 10204 3.1 material certificate so the mill grade is traceable.
Reading a spec in practice
A spec like “304, 100 mesh, 0.10 mm wire, plain weave, passivated” tells you everything you need: stainless 304, 100 openings per inch, 0.10 mm wire, square plain weave (≈154 µm aperture), corrosion-cleaned surface. If you only have a micron target instead, see our guide on mesh count vs. micron rating to translate between them. These specs are built into every filter disc, cylinder and custom filter element we make, so a clear cloth spec turns directly into a repeatable finished part.
Frequently Asked Questions
Does higher mesh count always mean finer filtration?
Usually, but not always — the opening also depends on wire diameter, so check the aperture.
Which number matters most for filtration?
The aperture (opening size), because it governs what passes through.
What if I only know the micron rating?
We convert it to a suitable mesh/wire/weave — just tell us the target and application.
Is a woven mesh aperture the same as a micron rating?
No. A woven aperture is a nominal physical opening; a micron rating is a performance figure. For an absolute cut-off, ask about sintered or Dutch-weave media.
Aperture = (25.4 mm ÷ mesh count) − wire diameter